Type: | Pharmaceutical Packaging Machinery |
---|---|
Finished Dosage Form: | Capsule |
Precision: | High Precision |
Certification: | GMP, ISO |
Voltage: | 220V |
Computerized: | Computerized |
Customization: |
---|
Suppliers with verified business licenses
S/N | Parameter |
1 | Scope of application for capsule size: After configuring the corresponding mold, it can be applied to various capsules with smooth and non viscous surfaces. |
2 | Capsule weight detection range :0-2000mg. |
3 | Dynamic detection accuracy: 1mg~2 mg |
4 | Display Accuracy:0.1mg. |
5 | Maximum 36 effective weighing channels, inspection speed : 1800~6000 capsules/min |
6 | Equipped with effective and accurate removal devices, which can effectively remove products beyond the weighing range, ensuring a weighing pass rate of 100%: |
7 | strain gauge load cell applied |
8 | All materials in contact with the capsule are 316 stainless steel or pharmaceutical grade materials (such as polytetrafluoroethylene), ensuring that they do not react, adsorb, or release adverse effects with the drug |
9 | The display touch screen can rotate 320 ° |
10 | The height of the device can be adjusted up and down by 50cm. |
11 | Operation control: 17 inch industrial touch screen. HMI language: Chinese and English. |
12 | The touch screen can display and set various parameters for operation, input weighing to eliminate upper and lower limits, display the cumulative number of qualified and unqualified items, and store relevant data reports. It can also display single value control charts. |
13 | It can display the weight check values of all channels simultaneously, or select a large digital display for a certain channel |
14 | Can display the weight curve and standard deviation of the first 20 capsules in any channel |
15 | Single channel calibration can be completed within 1 minute |
16 | The touch screen can be set with no less than three levels of users and passwords, and the top management can add or delete users, as well as change the passwords of low-level users. |
17 | Capable of recording daily production information and testing records, and able to store them. The storage capacity can ensure the storage of data for one year of continuous production, which can be exported from a computer. Equipped with data statistics and counting functions. |
18 | USB and Ethernet interfaces, supporting Modbus TCP protocol |
19 | The equipment can operate stably and reliably for 24 hours continuously |
20 | The design of the configuration system can prevent the loss of data and configuration parameters in the event of a power outage |
21 | Easy channel cleaning, all channels of the entire machine can be cleaned within 1 hour. |
22 | Easy maintenance, single channel disassembly and replacement can be completed within 1 hour. |
23 | The required compressed air pressure during normal operation is 0.4-0.6MPa. When the compressed air pressure is low, an alarm will be triggered and the machine will shut down |
24 | Can automatically reset to zero |
25 | Print detailed inspection reports directly through local USB or network printers |
26 | Equipped with sound and light alarm function |
27 | Power: 220V,50HZ |
28 | :220V,50HZ |
29 | All internal surfaces in contact with drugs shall be polished, and the stainless steel casing of the equipment shall be brushed or matte treated |
30 | When the weight inspection channel malfunctions, it can be closed at any time |
31 | elevator will be attached with checkweigher |
Suppliers with verified business licenses